IT码农库


Warning: Illegal string offset 'parentstr' in /home/wwwroot/chichuang/ku3.com.cn/include/func.class.php on line 246

Notice: Uninitialized string offset: 0 in /home/wwwroot/chichuang/ku3.com.cn/include/func.class.php on line 246
您当前所在位置:首页 > 栏目不存在

SUN常用系统维护命令

互联网 佚名2008-09-08
Warning: Illegal string offset 'id' in /home/wwwroot/chichuang/ku3.com.cn/show.php on line 80

Notice: Uninitialized string offset: 0 in /home/wwwroot/chichuang/ku3.com.cn/show.php on line 80

Warning: Illegal string offset 'classname' in /home/wwwroot/chichuang/ku3.com.cn/show.php on line 81

Notice: Uninitialized string offset: 0 in /home/wwwroot/chichuang/ku3.com.cn/show.php on line 81
6229
1、查看机型:Sun的小型机的机型都在面板上写着有,如NETRA T 1125, 还有比如ultra 5,ultra 10等等。2、查看cpu个数 (错误,不正确,因为sun中的top命令不能完全看到所有的cpu情况,与HP用法也不一样) # top CPU states: 99.3% idle, 0.1% user, 0.6% kerne

1、查看机型:Sun的小型机的机型都在面板上写着有,如NETRA T 1125,
还有比如ultra 5,ultra 10等等。

2、查看cpu个数 (错误,不正确,因为sun中的top命令不能完全看到所有的cpu情况,与HP用法也不一样)
# top
CPU states: 99.3% idle, 0.1% user, 0.6% kernel, 0.0% iowait, 0.0% swap
表示只有一个cpu

正确方法
用dmesg |grep cpu

便可以看到正确的 cpu个数了。

3、查看内存
#dmesg |grep mem
mem = 2097152K (0x80000000)
avail mem = 2087739392

4、查看磁盘的个数
#vxdisk list
DEVICE TYPE DISK GROUP STATUS
c0t0d0s2 sliced - - error
c0t0d0s7 simple c0t0d0s7 rootdg online
c1t0d0s2 sliced - - online
c1t1d0s2 sliced smpdg2 smpdg online
c1t2d0s2 sliced smpdbdg1 smpdbdg online
c2t0d0s2 sliced - - online
c2t1d0s2 sliced smpdg1 smpdg online
c2t2d0s2 sliced smpdbdg2 smpdbdg online


5、如何查看文件系统
#df -k
Filesystem kbytes used avail capacity Mounted on
/dev/dsk/c0t0d0s0 4032142 1050675 2941146 27% /
/proc 0 0 0 0% /proc
fd 0 0 0 0% /dev/fd
/dev/dsk/c0t0d0s6 7304977 29 7231899 1% /home
/dev/dsk/c0t0d0s5 4032142 402929 3588892 11% /opt
swap 3418392 32 3418360 1% /tmp
/vol/dev/dsk/c0t6d0/informix
201730 201730 0 100% /cdrom/informix
/dev/vx/dsk/smpdg/smpdg-stat
1055 9 941 1% /smpwork
/dev/vx/dsk/smpdg/lv_smp
17336570 128079 17035126 1% /sms

6、查看卷组、逻辑卷的位置
#cd /dev/vx/dsk/
比如smpdg等等都在该目录下了,然后再进入某个卷组目录就可以看到该卷组下
面的逻辑卷了。


 

7、如何创建卷组、逻辑卷、文件系统
A、创建smpdg逻辑卷组(假设现在是将c1t1d0 和c1t2d0两块物理磁盘来创建smcpdg逻辑卷组)
vxdisksetup -i c1t1d0 (格式化物理磁盘)
vxdisksetup -i c2t1d0
vxdg init smpdg smpdg1=c2t1d0 (将物理磁盘加入到逻辑卷组smpdg)
vxdg -g smpdg adddisk smpdg2=c1t1d0

然后再来创建逻辑卷、文件系统
vxassist -g smpdg -U fsgen make lv_smp 17200m layout=nolog smpdg1
vxassist -g smpdg mirror lv_smp layout=nostripe smpdg2
newfs -C -f /dev/vx/rdsk/smpdg/lv_smp

假设现在的一台机器上挂接到/sms
mkdir /sms
chown smp:smp /sms
vxvol -g smpdg startall
mount /dev/vx/dsk/smpdg/lv_smp /sms
umount /sms
vxvol -g smpdg stopall
vxdg deport smpdg

然后再在第二台机器上挂接到/sms
mkdir /sms
chown smp:smp /sms
vxdg import smpdg
vxvol -g smpdg startall
newfs -C -f /dev/vx/rdsk/smpdg/lv_smp
mount /dev/vx/dsk/smpdg/lv_smp /sms
umount /sms


备注:以上是创建一个共享的文件系统
往往由于smpdg要分配给某一个应用来使用,所以需要再来创建一个个逻辑机运行
时挂接的文件系统
vxassist -g smpdg -U fsgen make smpdg-stat 2m layout=nolog smpdg1
vxassist -g smpdg mirror smpdg-stat layout=nostripe smpdg2
newfs /dev/vx/rdsk/smpdg/smpdg-stat


B、创建smpdbdg逻辑卷组
创建卷组:
vxdisksetup -i c1t2d0
vxdisksetup -i c2t2d0
vxdg init smpdbdg smpdbdg1=c1t2d0
vxdg -g smpdbdg adddisk smpdbdg2=c2t2d0
vxassist -g smpdbdg -U fsgen make smpdbdg-stat 2m layout=nolog smpdbdg1
vxassist -g smpdbdg mirror smpdbdg-stat layout=nostripe smpdbdg2
newfs /dev/vx/rdsk/smpdbdg/smpdbdg-stat

创建逻辑卷:
vxassist -g smpdbdg -U gen make lv_rootdbs 128m layout=nolog smpdbdg1
vxassist -g smpdbdg mirror lv_rootdbs layout=nostripe smpdbdg2
vxassist -g smpdbdg -U gen make lv_logdbs 300m layout=nolog smpdbdg1
vxassist -g smpdbdg mirror lv_logdbs layout=nostripe smpdbdg2
vxassist -g smpdbdg -U gen make lv_phydbs 100m layout=nolog smpdbdg1
vxassist -g smpdbdg mirror lv_phydbs layout=nostripe smpdbdg2
vxassist -g smpdbdg -U gen make lv_tempdbs 1000m layout=nolog smpdbdg1
vxassist -g smpdbdg mirror lv_tempdbs layout=nostripe smpdbdg2
vxassist -g smpdbdg -U gen make lv_svcchunk1 2000m layout=nolog smpdbdg1
vxassist -g smpdbdg mirror lv_svcchunk1 layout=nostripe smpdbdg2
vxassist -g smpdbdg -U gen make lv_svcchunk2 2000m layout=nolog smpdbdg1
vxassist -g smpdbdg mirror lv_svcchunk2 layout=nostripe smpdbdg2
vxassist -g smpdbdg -U gen make lv_svcchunk3 2000m layout=nolog smpdbdg1
vxassist -g smpdbdg mirror lv_svcchunk3 layout=nostripe smpdbdg2
vxassist -g smpdbdg -U gen make lv_recchunk1 2000m layout=nolog smpdbdg1
vxassist -g smpdbdg mirror lv_recchunk1 layout=nostripe smpdbdg2
vxassist -g smpdbdg -U gen make lv_recchunk2 2000m layout=nolog smpdbdg1
vxassist -g smpdbdg mirror lv_recchunk2 layout=nostripe smpdbdg2
vxassist -g smpdbdg -U gen make lv_recchunk3 2000m layout=nolog smpdbdg1
vxassist -g smpdbdg mirror lv_recchunk3 layout=nostripe smpdbdg2
vxassist -g smpdbdg -U gen make lv_recchunk4 2000m layout=nolog smpdbdg1
vxassist -g smpdbdg mirror lv_recchunk4 layout=nostripe smpdbdg2
vxassist -g smpdbdg -U gen make lv_recchunk5 1700m layout=nolog smpdbdg1
vxassist -g smpdbdg mirror lv_recchunk5 layout=nostripe smpdbdg2

C、附逻辑卷的属性
vxedit -g smpdg -v set user=smp group=smp lv_smp
vxedit -g smpdbdg -v set user=informix group=informix mode=660 lv_rootdbs
vxedit -g smpdbdg -v set user=informix group=informix mode=660 lv_logdbs
vxedit -g smpdbdg -v set user=informix group=informix mode=660 lv_phydbs
vxedit -g smpdbdg -v set user=informix group=informix mode=660 lv_tempdbs
vxedit -g smpdbdg -v set user=informix group=informix mode=660 lv_svcchunk1
vxedit -g smpdbdg -v set user=informix group=informix mode=660 lv_svcchunk2
vxedit -g smpdbdg -v set user=informix group=informix mode=660 lv_svcchunk3
vxedit -g smpdbdg -v set user=informix group=informix mode=660 lv_recchunk1
vxedit -g smpdbdg -v set user=informix group=informix mode=660 lv_recchunk2
vxedit -g smpdbdg -v set user=informix group=informix mode=660 lv_recchunk3
vxedit -g smpdbdg -v set user=informix group=informix mode=660 lv_recchunk4
vxedit -g smpdbdg -v set user=informix group=informix mode=660 lv_recchunk5

备注:在SUN的机器中在给逻辑卷付属性的时候,等于用chown、chmod来作。


8、如何删除卷组
其实也就是去激活和倒出的过程,然后再来对物理磁盘重新格式化就完了。
vxvol -g smpdbdg stopall
vxdg deport smpdbdg
vxdisksetup -i c1t0d0
vxdisksetup -i c2t1d0
......

这样做了之后就不会再有/dev/vx/smpdbdg目录了。

9、如何建立共享卷组
在第一台机器上先建立卷组,假设已经建设好卷组smpdg,现在要在第二台机器上建立共享卷组smpdg,
则先在的一台机器上将smpdg去激活、并且倒出smpdg:
smcp01>vxvol -g smpdg stopall
smcp01>vxdg deport smpdg

再来在第二台机器上激活、导入smpdg:
smcp02>vxdg import smpdg
smcp02>vxvol -g smpdg startall

切换后对用以下三个命令进行查看是否切换成功:
vxdg list //用于查看逻辑卷组的信息
vxdisk list //用于查物理磁盘的信息
vxprint -vt //用于查看所有卷的信息


 

10、如何查看磁盘的大小

方法一:
#format
然后选择盘的代号,回车进入下一级菜单,再选inquiry,就得到该盘的大小信
息,比如:
Vendor: FUJITSU
Product: MAN3184M SUN18G
Revision: 1502

注意:format是一个功能强大的磁盘诊断工具。

方法二:
#cd /opt/SUNWexplo/bin/
运行explorer得到磁盘的信息包,是一个目录,进入该目录,就发现有一个
disks目录,进入该目录发现有一个diskinfo文件,用如下命令看各个磁盘
的大小:

0: rmt/0ln HP C1537A L706 62########
1: c0t0d0 FUJITSU MAJ3182M SUN18G 0804 0041P90050##
2: c1t0d0 SEAGATE ST318203LSUN18G 034A 0025H54125##
3: c1t1d0 SEAGATE ST318203LSUN18G 034A 0026H70087##
4: c1t2d0 FUJITSU MAJ3182M SUN18G 0804 0046P66422##
5: c2t0d0 SEAGATE ST318203LSUN18G 034A 0026G30220##
6: c2t1d0 SEAGATE ST318203LSUN18G 034A 0026H59041##
7: c2t2d0 FUJITSU MAJ3182M SUN18G 0804 0051P91980##
8: ses0 SYMBIOS D1000 2 O8# SAF-
9: ses1 SYMBIOS D1000 2 O8# SAF-

11、查看informix的版本
#su - informix
informix>onstat -
这样可以看到informix的版本。

12、收集信息的工具
#cd /opt/SUNWexplo/bin/explorer
#explorer
运行之后得到一个文件夹和该文件夹的压缩包*.gz。我们可以进入该
结果文件夹,在该文件夹中有各种需要查看的信息。

13、双机的脚本文件
#cd /opt/SUNWcluster/ha/smpwork
在ha下面有双机应用的文件夹,如smpwork,在该文件夹下面又有各种
双机应用的配置文件。

14、双机的维护命令集

首先在节点smcp01机上启动cluster:
# scadmin startcluster smcp01 smcp
然后在节点smcp02机上将本节点启动:
# scadmin startnode
启动后观察cluster状态的命令是 :
# hastat //该命令可以显示cluster、节点、
逻辑机和Data service的状态,以及一些历史运行信息。

# get_node_status //该命令可以显示所在节点的节点号、公用网卡的状态等信息。


从图形化的本地终端(假设其IP地址为ip)中以smcp用户的身份登
录到SMCP主机(注意应使用SMCP的逻辑机地址)
% telnet smcpwork
在SMCP主机上设置环境变量DISPLAY
% setenv DISPLAY ip:0.0
在本地终端中执行
% xhost +
手工启动OAM
% oam&
以OAM操作员登录

分别在两个节点smcp01机和smcp02机上执行:
# scadmin stopnode
该命令使当前所在节点停止在cluster中运行,而且在两个节点上要分别执行该命令。

例如将smcpwork切换到节点smcp02上运行可以输入:
#scadmin switch smcp smcp02 smcpwork
例如将querywork切换到节点smcp02上运行可以输入:
#haswitch smcp02 querywork

hareg命令通过以下开关参数将Data service注册和激活
-r 将指定的Data service注册到cluster中
-u 将指定的Data service从cluster中取消注册
-y 激活指定的Data service,使其状态为On
-Y 激活cluster中所有的Data service,使其状态为On
-n 去激活指定的Data service,使其状态为Off
-N 去激活cluster中所有的Data service,使其状态为Off
hareg不带任何参数时可以查看所有Data service的当前状态
Data service只有在注册到cluster中之后,才会具有On或者Off的状态,
处于On状态的Data service可以正常的对外提供服务
而处于Off状态的Data service是停止对外服务的。如果Data service被取消了注册,
必须重新注册才能在cluster中运行起来。当然,使用hareg命令的前提是cluster
已经启动并正常运行。


从图形化的本地终端(假设其IP地址为ip0)中以root用户的身份登录到SMCP主机
(假设其IP地址为ip1):
在本地终端中执行
% xhost +
% telnet ip1
再在SMCP主机上设置环境变量DISPLAY
# DISPLAY =ip1:0.0
# export DISPLAY
# vxva

大图广告(830*140)